Bridge (ID- 3299 ) Inventory Report

Muyalgaon gadera On Chainage 107.850 of Uttarkashi Ghansali Tilwara state highway

Data Yet Not Finalized

Last Rated On 03 Jun 2025

Rating 0.00%

Categorized As

XXXXX on XX-XX-XXXX

In District : Tehri Under Division : TD Ghansaali

General

Bridge Type : Motor Bridge High Level
Structure No : 107/3
Feature Intersected : Muyalgaon gadera
Name of Bridge : Muyalgaon gadera
Nearest Town : Muyalgaon
Latitude (Northing) : 30.39619160
Longitude (Easting) : 78.72200270
Construction Year : 2024
Inventory Year : 2025

Geometric

Overall length (in meter) : 18.29
Total No of Span : 1
Maximuam Span (in meter) : 18.29
Span Arragment : 1*18.288
No of Lane : 1.000
Overall Width (m) : 4.500
Carriageway Width (m) : 4.250
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 6.500
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level :
OFL Ordinary Flood Level :
LWL Low Water Level :
Design Velocity (m/Sec) :
Design Discharge (Cumecs) :
Soffit Level at Centre :
Road Level at Centre :
Design Scour Level at Pier :
Design Scour Level at Abutments : 0.000
Exposure Condition : Moderate
Seismic Importance factor : 0.0
Design Loading : Class 70R
Load Rating : Class 70R

Super-Structure

Superstructure Type : Bailey
Superstructure Material : Steel
Wearing Coat Type : Not Provided
Expension Joint Type : Not Provided
Railing/Crash Barrier type : Not Provided
Bearing type : Not Provided

Sub-Structure

Founding Strata : Bouldery
Abutment Foundation Type : Raft
Pier Foundation Type : NA
No of Piers : 0
Abutment Type : Stone Masonry
Pier Type : NA

Protection Work

Bank Protection Left Side of Up-stream : protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided