Bridge (ID- 3117 ) Inventory Report

Alaknanda River Bridge On Chainage 0.500 of Kirtinagar Badiyar Dhaurangi Saurakhal motor road

Data finalized On 07 Mar 2025

By Er. Alka Rani

Last Rated On 05 Jun 2024

Rating 47.84%

Categorized As

XXXXX on XX-XX-XXXX

In District : Tehri Under Division : TD Kirtinagar

General

Bridge Type : Motor Bridge High Level
Structure No : 0
Feature Intersected : Alaknanda
Name of Bridge : Alaknanda River Bridge
Nearest Town : Kirtinagar
Latitude (Northing) : 30.12510000
Longitude (Easting) : 78.45060000
Construction Year : 1957
Inventory Year : 2010

Geometric

Overall length (in meter) : 85.34
Total No of Span : 2
Maximuam Span (in meter) : 70.00
Span Arragment : 1x70+1x15.34
No of Lane : 1.000
Overall Width (m) : 5.000
Carriageway Width (m) : 4.200
RS Footpath Width (m) : 0.000
LS Footpath Width (m) : 0.000
Approch Width i/c Shoulders (m) : 6.000
Gradient (%age) : 0
Skew Angle (degree) : 0.00
Radius of Curve in Plan (if Any) : 0.00

Design Data

HFL Highest Flood Level : 3000.000
OFL Ordinary Flood Level : 2000.000
LWL Low Water Level : 1500.000
Design Velocity (m/Sec) : 0.00
Design Discharge (Cumecs) : 0.00
Soffit Level at Centre : 25.000
Road Level at Centre : 25.000
Design Scour Level at Pier : 0.000
Design Scour Level at Abutments : 0.000
Exposure Condition : Moderate
Seismic Importance factor : 1.0
Design Loading : Class B
Load Rating : Class B

Super-Structure

Superstructure Type : Cable stayed
Superstructure Material : Steel
Wearing Coat Type : Cement Concrete
Expension Joint Type : Single Strip/Box Seal Joint
Railing/Crash Barrier type : Tubular steel
Bearing type : Roller & Rocker

Sub-Structure

Founding Strata : Rocky
Abutment Foundation Type : Open
Pier Foundation Type : Open
No of Piers : 1
Abutment Type : Stone Masonry
Pier Type : Stone Masonry

Protection Work

Bank Protection Left Side of Up-stream : no protection work provided
Bank Protection Right Side of Up-stream : no protection work provided
Bank Protection Left Side of Down-stream : no protection work provided
Bank Protection Right Side of Down-stream : no protection work provided
Floor Protection on Up-stream : no protection work provided
Floor Protection on Down-stream : no protection work provided
Tratment for Corrosion Protection (if any) : no special treatment provided